Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Arq. bras. oftalmol ; 79(5): 294-298, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: biblio-827967

ABSTRACT

ABSTRACT Purpose: To evaluate visual acuity and transient pattern reversal (PR) visual evoked potentials (VEPs) in the fellow eyes of children with strabismic and/or anisometropic amblyopia. Methods: Children diagnosed with strabismic and/or anisometropic amblyopia were recruited for electrophysiological assessment by VEPs. Monocular grating and optotype acuity were measured using sweep-VEPs and an Early Treatment Diabetic Retinopathy Study chart, respectively. During the same visit, transient PR-VEPs of each eye were recorded using stimuli subtending with a visual angle of 60', 15', and 7.5'. Parameters of amplitude (in μV) and latency (in ms) were determined from VEP recordings. Results: A group of 40 strabismic and/or anisometropic amblyopic children (22 females: 55%, mean age= 8.7 ± 2.2 years, median= 8 years) was examined. A control group of 19 healthy children (13 females: 68.4%, mean age= 8.2 ± 2.6 years, median= 8 years) was also included. The fellow eyes of all amblyopes had significantly worse optotype acuity (p=0.021) than the control group, regardless of whether they were strabismic (p=0.040) or anisometropic (p=0.048). Overall, grating acuity was significantly worse in the fellow eyes of amblyopes (p=0.016) than in healthy controls. Statistically prolonged latency for visual angles of 15' and 7.5' (p=0.018 and 0.002, respectively) was found in the strabismic group when compared with the control group. For the smaller visual stimulus (7.5'), statistically prolonged latency was found among all fellow eyes of amblyopic children (p<0.001). Conclusions: The fellow eyes of amblyopic children showed worse optotype and grating acuity, with subtle abnormalities in the PR-VEP detected as prolonged latencies for smaller size stimuli when compared with eyes of healthy children. These findings show the deleterious effects of amblyopia in several distinct visual functions, mainly those related to spatial vision.


RESUMO Objetivo: Avaliar a acuidade visual e os potenciais visuais evocados transientes por reversão de padrões no olho contralateral de crianças com ambliopia estrabísmica e/ou anisometrópica. Métodos: Foram avaliados os potenciais visuais evocados de crianças com ambliopia estrabísmica e/ou anisometrópica. As acuidades visuais monoculares de grades e de optotipos foram mensuradas utilizando o PVE de varredura e a tabela EDTRS, respectivamente. Na mesma visita, foram registrados os PVERP transients de cada olho usando estímulos de ângulo visual de 60'; 15' e 7,5'. Parâmetros de amplitude (em microvolts) e latência (em milissegundos) foram determinados para os registros dos potenciais visuais evocados. Resultados: Um grupo de 40 crianças amblíopes estrábicas e/ou anisometrópicas (22 meninas - 55%, media idade= 8,7 ± 2,2, mediana= 8) foi examinado. Um grupo de 19 crianças saudáveis (13 meninas 68,4%, media idade= 8,2 ± 2,6, mediana= 8) de controle também foi incluído. A acuidade visual por optotipos foi significativamente pior (p=0,021) nos olhos contralaterais de todos os amblíopes, quando comparado com o grupo controle, independentemente se estrábico (p=0,040) ou anisometrópico (p=0,048). No geral, a acuidade visual por grades foi significativamente pior nos olhos contralaterais dos amblíopes (p=0,016), quando comparados com o grupo controle. Foi encontrada latência estatisticamente prolongada para ângulos visuais de 15' (p=0,018) e 7,5' (p=0,002) no grupo estrábico, quando comparado com o grupo controle. Para o menor estímulo visual (7,5') foi encontrada latência estatisticamente prolongada nos olhos contralaterais de todas crianças amblíopes (p<0,001). Conclusões: Os olhos contralaterais de crianças amblíopes mostraram pior acuidade visual de optotipo e de resolução de grades, com alterações sutis nos PVERP, detectadas pelas latências prolongadas para estímulos de menor tamanho, quando comparados com os olhos de crianças saudáveis. Estes resultados mostram os efeitos deletérios da ambliopia em várias funções visuais distintas, principalmente relacionadas à visão espacial.


Subject(s)
Humans , Male , Female , Child , Adolescent , Visual Acuity/physiology , Amblyopia/physiopathology , Strabismus/physiopathology , Evoked Potentials, Visual/physiology , Eye/physiopathology , Photic Stimulation , Reference Values , Time Factors , Case-Control Studies , Cross-Sectional Studies , Prospective Studies , Analysis of Variance , Statistics, Nonparametric
2.
Rev. bras. oftalmol ; 74(6): 339-344, nov.-dez. 2015. tab, graf
Article in English | LILACS | ID: lil-767076

ABSTRACT

RESUMO Objetivo: Determinar o volume médio das gotas produzidas pelos colírios lubrificantes em diferentes ângulos de inclinação e determinar o custo médio do tratamento. Métodos: Determinação do volume da gota de 3 frascos originais dos colírios lubrificantes Artelac®, Hylo Comod®, Lacrima® Plus, Systane® UL, Lacrifilm®, Hyabak®, Lacribell®, Ecofilm®, Mirugell®, Plenigell®, Fresh Tears®, Optive® e Endura® à inclinação de 90º e 45º. Determinou-se o número médio de gotas em cada frasco e foi feita avaliação farmacoeconômica dos colírios. Resultados: O volume das gotas variou de 32,2 a 64,0 µL a 45o e de 29,1 a 65,1 µL a 90o. A diferença entre as gotas em cada inclinação foi de 2 a 24% e o custo anual dos colírios de acordo com a inclinação variou de R$2,73 a R$130,73. A Duração Máxima de Tratamento (DMT) foi de 29,3 a 51,4 dias na inclinação de 45o, e de 28,8 a 48,4 dias a 90º, sendo que a diferença na DMT foi de 0,5 até 8 dias a mais ou a menos, de acordo com a marca. Conclusão: Nenhum dos colírios estudados apresentou gotas ideais para o olho humano, levando a um desperdício do produto e maior custo para o fabricante e para o consumidor. Percebemos que existe uma variação significativa no volume da gota de acordo com a inclinação do frasco, e que uma variação maior do que 10% traria impactos financeiros para o paciente.


ABSTRACT Objective: To determine the mean drop volume produced by artificial tear solutions in different inclination angles and to determine the mean cost of the treatment. Methods: The drop volume of 3 original bottles of the artificial tear solutions Artelac®, Hylo Comod®, Lacrima® Plus, Systane® UL, Lacrifilm®, Hyabak®, Lacribell®, Ecofilm®, Mirugell®, Plenigell®, Fresh Tears®, Optive® and Endura® were determined at the inclination of 90º and 45º. The mean number of drops in each bottle was determined and a pharmacoeconomic evaluation of the drops was made. Results: The drop volume ranged from 32.2 to 64.0 µL at 45º and from 29.1 to 65.1 µL at 90º. The difference between drops in each inclination varied from 2 to 24%. The annual cost was from R$2,73 to R$130,73 according to the inclination of the bottle. The Maximum Duration of Treatment (MDT) was from 29.3 to 51.4 days at 45o and from 28.8 to 48.4 days at 90º, being the difference in MDT from 0.5 to 8 more or less days depending on each brand. Conclusion: None of the collyria studied presented ideal drops for human eyes, leading to a waste of the product and higher cost for the manufacturer and the consumer. We noted that there is a significant variation in the drop volume according to the inclination of the bottle, and that a variation of over 10% would bring financial impact for the patient.


Subject(s)
Economics, Pharmaceutical , Densitometry/methods , Lubricant Eye Drops/administration & dosage , Lubricant Eye Drops/economics , Lubricant Eye Drops/standards , Instillation, Drug , Drug Costs , Drug Packaging/economics , Drug Packaging/standards
3.
Arq. bras. oftalmol ; 73(2): 129-134, Mar.-Apr. 2010. graf, tab
Article in Portuguese | LILACS | ID: lil-548141

ABSTRACT

OBJETIVOS: Avaliar os efeitos do acetato de triancinolona intravítreo em pacientes com edema macular diabético difuso na acuidade visual e pressão intraocular. Relatar os possíveis efeitos adversos e analisar a possível relação da idade dos pacientes com as variações da acuidade visual e pressão intraocular. MÉTODOS: O ensaio clínico controlado incluiu 14 pacientes (28 olhos), sendo que 14 olhos receberam injeção de 4 mg de acetato de triancinolona intravítreo para o tratamento de edema macular diabético difuso. O grupo tratado foi comparado a um grupo controle de 14 olhos sem edema macular diabético difuso. O tempo de seguimento foi de três meses. RESULTADOS: Os picos de pressão intraocular >21 mmHg ocorreram em 28,57 por cento, com diferença significante entre a pressão intraocular do grupo tratado com o grupo controle na primeira semana após o tratamento. A acuidade visual mostrou uma significativa melhora quando comparada com o grupo controle desde o segundo dia após o tratamento. Não houve associação entre a idade com as variações da acuidade visual e a pressão intraocular. CONCLUSÃO: O acetato de triancinolona intravítreo mostrou-se ser eficiente para melhorar a acuidade visual em pacientes com edema macular diabético difuso, nos primeiros três meses de tratamento. A incidência de hipertensão intraocular foi de 28,57 por cento, podendo ser caracterizada como de fácil controle.


PURPOSE: To evaluate the effect of intravitreal triamcinolone acetonide in patients with diffuse diabetic macular edema on the visual acuity and intraocular pressure. To report the potential adverse events and to analyze the potential relationship between age and visual acuity and intraocular pressure variability. METHODS: This clinical controlled study included 14 patients (28 eyes), 14 of the eyes received an intravitreal injection of 4 mg triamcinolone acetonide for the treatment of diabetic macular edema. The study group was compared to a control group of 14 eyes, without diabetic macular edema. The follow-up period was of 3 months. RESULTS: Pressure spikes >21 mmHg occurred in 28.7 percent of eyes, with a significant difference of intraocular pressure between the study group and the control group in the first week after treatment. Visual acuity showed a significant improvement when compared with the control group since the second day after the treatment. There was no association between age and variability of visual acuity and intraocular pressure. CONCLUSION: Intravitreal triamcinolone acetonide showed to be effective for improving visual acuity in patients with diabetic macular edema, in the first three months of treatment. The incidence of intraocular hypertension was 28.7 percent, easily manageable.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Anti-Inflammatory Agents/administration & dosage , Diabetic Retinopathy/drug therapy , Intraocular Pressure/drug effects , Macular Edema/drug therapy , Triamcinolone Acetonide/administration & dosage , Visual Acuity/drug effects , Anti-Inflammatory Agents/adverse effects , Case-Control Studies , Diabetic Retinopathy/complications , Follow-Up Studies , Macular Edema/etiology , Triamcinolone Acetonide/adverse effects , Vitreous Body
4.
Arq. bras. oftalmol ; 70(6): 939-942, nov.-dez. 2007. tab
Article in Portuguese | LILACS | ID: lil-474098

ABSTRACT

OBJETIVO: Identificar os tipos de desvios oculares e suas freqüências nos pacientes encaminhados ao ambulatório de motilidade ocular extrínseca do Hospital do Servidor Público Estadual de São Paulo. MÉTODOS: Foram revisados 935 prontuários do ambulatório de motilidade ocular extrínseca do ano de 2005. Os pacientes foram avaliados quanto à idade, sexo e tipo de desvio apresentado na posição primária do olhar, sendo submetidos esses dados à avaliação estatística. RESULTADOS: A esotropia foi o desvio com maior prevalência na população estudada (44,52 por cento). Neste grupo houve predomínio de indivíduos do sexo masculino (p=0,001). Este desvio foi mais freqüente na faixa etária de 0-2 anos (p=0,009). Já a exotropia (12,25 por cento) mostrou-se mais freqüente entre as mulheres (p=0,046), sendo predominante na faixa etária superior aos 47 anos de idade (p=0,001) CONCLUSÃO: Observou-se maior número de esodesvios em relação aos exodesvios. As esotropias foram mais freqüentes no sexo masculino em faixas etárias mais jovens. Já as exotropias se apresentaram em maior número no sexo feminino em faixas etárias mais elevadas. O maior número de exoforias foi encontrado em pacientes com idades entre 16 e 20 anos.


PURPOSE: To evaluate the frequency of different types of ocular deviations in patients referred to the strabismus sector at the Hospital do Servidor Público Estadual de São Paulo - Brazil. METHODS: A retrospective study of 935 records of patients examined at the strabismus sector in 2005 was conducted to evaluate sex, age and types of misalignments in the primary position. Statistical analysis was applied to these data. RESULTS: Esotropia was the most prevalent misalignment in this population (44.52 percent). There were more males in this group (p=0.001) with a predominance of the age group 0-2 years (p=0.009). Exotropia (12.25 percent) was more frequent in females (p=0.046) in the age group 46 years and over (p=0.001). CONCLUSION: Esodeviations were more frequent than exodeviations. Esotropia was more prevalent in males early in life, while exotropia was more frequent in older females. The larger number of exophorias was found in the age group 16-20 years.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Middle Aged , Esotropia/epidemiology , Exotropia/epidemiology , Age Distribution , Brazil/epidemiology , Chi-Square Distribution , Prevalence , Retrospective Studies , Sex Distribution
5.
Arq. bras. oftalmol ; 70(6): 943-948, nov.-dez. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-474099

ABSTRACT

INTRODUÇÃO: Esclerose múltipla é uma doença desmielinizante idiopática, podendo acometer o nervo óptico com perda visual unilateral aguda que pode ser observada através do potencial visual evocado (PVE), definindo tal exame como de grande validade para o estudo pré-quiasmático das vias visuais na esclerose múltipla. OBJETIVO: Analisar os achados dos potenciais visuais evocados por reversão de padrões em pacientes com diagnóstico prévio de esclerose múltipla e sua comparação com a acuidade visual. MÉTODOS: Vinte e quatro pacientes com diagnóstico definido de esclerose múltipla foram submetidos ao PVE por reversão de padrões no período de outubro de 2001 a março de 2007. RESULTADOS: Na resposta do componente P100, nos estímulos de 15' e 1º, se observou que 19 olhos apresentaram resposta de latência até 115 ms em ambas as estimulações, coincidindo também em 6 olhos que apresentaram resposta de latência entre 116 a 135 ms, em 11 olhos que apresentaram resposta de latências superiores a 135 ms, e em 4 olhos que não apresentaram respostas às estimulações. Correlacionando a acuidade visual com a latência de P100 para 15', obtemos na correlação de Pearson r= 0,85 com p= 0,000000123, e para 1º, r= 0,87 com p= 0,0000000338. CONCLUSÃO: Aproximadamente 60,4 por cento dos pacientes apresentaram anormalidades no PVE por padrões reversos. Contudo, a correlação entre a latência de P100 (15' e 1º) e a acuidade visual foi estatisticamente significativa, assim sendo, quanto melhor a acuidade visual, melhor será sua resposta aos estímulos do PVE por reversão de padrões.


INTRODUCTION: Multiple sclerosis is an idiopathic demyelinating disease that may affect the optic nerve leading to acute unilateral visual loss, which could be observed by means of evoked visual potential (VEP). This exam is much valued for studying prechiasmatic visual paths in multiple sclerosis. PURPOSE: To analyze the findings of pattern reversal VEP in patients with prior diagnosis of multiple sclerosis and to compare them to visual acuity. METHODS: Twenty-four patients with a definite diagnosis of multiple sclerosis were submitted to pattern reversal VEP from October 2001 to March 2007. RESULTS: In P100 component response, at 15' and 1º stimuli, 19 eyes presented latency response up to 115 ms in both stimuli, which coincided in 6 eyes with latency response between 116 and 135 ms; 11 eyes had a latency response higher than 135 ms, and four eyes did not respond to stimuli. Correlating visual acuity with P100 latency for 15', in Pearson r correlation, r=0.85 with p=0.000000123, and for 1º, r = 0.87 with p=0.0000000338. CONCLUSION: Approximately 60.4 percent of patients presented abnormalities. However, the correlation between the P100 latency (15' and 1º) and visual acuity was statistically significant; therefore the better the visual acuity, the better the response to stimuli of the pattern-reversal VEP.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Evoked Potentials, Visual/physiology , Multiple Sclerosis/physiopathology , Pattern Recognition, Visual/physiology , Visual Acuity/physiology , Data Interpretation, Statistical , Multiple Sclerosis/complications , Reaction Time/physiology , Time Factors , Vision Disorders/etiology , Visual Pathways/physiopathology
6.
Arq. bras. oftalmol ; 70(2): 360-362, mar.-abr. 2007. ilus
Article in Portuguese | LILACS | ID: lil-453184

ABSTRACT

A síndrome de Brown é caracterizada por grande limitação de elevação em adução, elevação ligeiramente diminuída ou normal na abdução, anisotropia em "Y" ou "V", intorção do olho em supraversão e ducção forçada positiva. Sua causa se deve à inelastibilidade do músculo oblíquo superior ou por sua contenção em sua própria bainha. A hipermobilidade articular benigna é doença hereditária do tecido conectivo caracterizada por aumento da mobilidade em diversas articulações. Sua prevalência é muito variável em relação à idade, sexo e etnia, variando de 2 a 35 por cento em homens e de 5 a 57 por cento e mulheres. Neste relato os autores descrevem um caso de síndrome de Brown associada com hipermobilidade articular benigna e atentam para a associação pouco referida na literatura. J.C.S, masculino, 6 anos de idade, pardo, estudante, foi encaminhado à Universidade de Santo Amaro com queixa de exotropia há dois anos que aumentava na supraversão. Paciente com o diagnóstico de síndrome de Brown bilateral teve o diagnóstico de hipermobilidade articular benigna pelo Reumatologista. O paciente com hipermobilidade articular benigna pode desenvolver sintomas articulares como artralgia devido a uma inflamação articular. Acreditamos na possibilidade de que síndrome de Brown possa ter ocorrido devido a processo inflamatório na tróclea que teve início devido a hipermobilidade articular benigna.


Brown's syndrome is characterized by a limitation of elevation in adduction, slight or normal limitation of elevation in abduction, divergence in straight upgaze (V-pattern), intorsion in upgaze and positive forced duction. It is caused by a tight or inelastic superior oblique tendon. Benign joint hypermobility is a hereditary disease of the connective tissue characterized by an increase of mobility in diverse joints. Its prevalence is very changeable regarding age range, sex and ethnicity, varying from 2 to 35 percent in men and 5 to 57 percent in women. In this case the authors describe a case of Brown's syndrome associated with Benign joint hipermobility and call attention to a little described association in the literature. J.C.S, male, 6 years old, mulatto, student, was referred to the University of Santo Amaro with complaint of exotropia for 2 years that it increased in supraversion. The patient with the diagnosis of bilateral Brown's syndrome, was diagnosed as having benign joint hipermobility by the reumatologist. The patient with benign joint hipermobility can develop symptoms such as arthralgia caused by a joint inflammation. We believe in the possibility that Brown syndrome has occurred, caused by an inflammatory process in the trochlea that started because of the benign joint hypermobility.


Subject(s)
Humans , Male , Child , Joint Instability/complications , Ocular Motility Disorders/etiology , Eye Movements , Exotropia/complications , Ocular Motility Disorders/diagnosis , Oculomotor Muscles/physiopathology , Syndrome , Tomography, X-Ray Computed , Visual Acuity
7.
Arq. bras. oftalmol ; 64(4): 283-286, jul.-ago. 2001. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-292575

ABSTRACT

Objetivo: Desenvolvimento de metodologia para avaliar a torçäo ocular reflexa. Médotos: Modificaçöes no ceratômetro de Hemholtz que permitem a avaliaçäo da ceratometria de ambos os olhos na posiçäo primária do olhar e durante as inclinaçöes laterais da cabeça, para a direita e para a esquerda a 30 graus. Foram examinados um total de 16 pacientes e 32 olhos com astigmatismo refracional de 0,50 a 3,50 dioptrias (média de 1,18 +/- 0,61). Resultados: Registrou-se intorçäo reflexa semelhante no olho direito e esquerdo (5,22 +/-3,91 para olho esquerdo e 5,31 +/- 4,23 para olho direito). O mesmo ocorreu com os valores de extorçäo reflexa (7,84 +/- 4,79 para olho esquerdo e 7,78 +/- 4,09 para olho direito). Conclusäo: As modificaçöes no ceratômetro de Helmholtz permitiram a observaçäo e quantificaçäo da torçäo ocular reflexa em pacientes com astigmatismo, através de metodologia inédita e de fácil reprodutibilidade.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Astigmatism/diagnosis , Diagnostic Techniques, Ophthalmological , Eye Movements/physiology , Reflex, Vestibulo-Ocular/physiology , Optical Rotation , Visual Acuity/physiology
8.
Arq. bras. oftalmol ; 64(3): 199-201, maio-jun. 2001. tab, graf
Article in Portuguese | LILACS | ID: lil-289240

ABSTRACT

Introduçäo: Convergência acomodativa (CA) é a convergência induzida por determinado grau de acomodaçäo (A). Apesar de haver inúmeras técnicas cirúrgicas descritas para correçäo de esotropias, a presença de grandes incomitâncias longe/perto associadas acrescenta o desafio de se evitar o surgimento de exodesvio para longe, ou esodesvio residual para perto. Objetivo: Comparar as correçöes cirúrgicas obtidas com o duplo retrocesso dos retos mediais em pacientes esotrópicos quanto aos desvios de longe e de perto, comparando-se baixas e altas hipermetropias. Material: Foram analisados retrospectivamente os prontuários de 33 pacientes esotrópicos com incomitância longe/perto, operados com duplo retrocesso dos retos mediais na Santa Casa de Säo Paulo entre 1980 e 1990. Os pacientes foram divididos em 2 grupos: com mais de 3,50 dioptrias esféricas (DE) de hipermetropia e com menos de 3,50 DE. Resultados: A magnitude da correçäo obtida no grupo I foi de 18,18 dioptrias prismáticas (DP) (72,72 por cento de correçäo) para longe e 27,64 DP (62,36 por cento) para perto. A correçäo no grupo II foi de 20,20 DP para longe (87,83 por cento) e 34,60 DP (82,78 por cento) para perto. Conclusäo: Näo há diferença (estatisticamente significante) na reduçäo da incomitância longe/perto entre os pacientes com hipermetropia até 3,50 DE e pacientes com hipermetropia maior que 3,50 DE. O valor absoluto da reduçäo em dioptrias do desvio para perto foi maior do que o encontrado para longe, no entanto, em porcentagem, a correçäo do desvio foi semelhante entre as medidas para perto e para longe.


Subject(s)
Humans , Child, Preschool , Child , Adolescent , Adult , Accommodation, Ocular , Esotropia/surgery , Oculomotor Muscles/surgery , Hyperopia/physiopathology , Postoperative Period , Preoperative Care , Retrospective Studies
9.
Arq. bras. oftalmol ; 62(2): 186-8, mar.-abr. 1999. ilus
Article in Portuguese | LILACS | ID: lil-251248

ABSTRACT

Neste trabalho, os autores relatam dois casos de síndrome de Chandler. Foram realizados exames oftalmológicos de rotina além de biomicroscopia ultra-sônica e microscopia especular para complementar o diagnóstico. Säo discutido a fisiopatologia e o tratamento da doença


Subject(s)
Humans , Female , Middle Aged , Cornea/physiopathology , Iris Diseases
SELECTION OF CITATIONS
SEARCH DETAIL